Ballistic Resistant Transparency (Decorative Blass Block)

This ballistic resistant transparent glass block armor is manufactured from 3" of solid and semi-solid glass. The Vistabrik® line offers two architectural styles to select from. The Thickset® line offers slightly less protection with three architectural styles to select from. Both the Vistabrik® and Thickset® lines have 8"x 8" dimensions. Each of the glass block lines offer substantial noise resistance from an STC rating of 50 for the Thickset® lines to 53 for the Vistabrik® lines. Each are code approved for hurricane resistance.

Vistabrik®
Solid Glass Block
Vistabrik® Solid Glass Block - Vue® Pattern
Vistabrik® Solid Glass Block
Vue® Pattern-good visibility
Vistabrik® Solid Glass Block - Stipple Pattern
Vistabrik® Solid Glass Block
Stipple Finish-adds privacy

A Premiere Series product, Vistabrik® solid glass blocks form durable, ADA-acceptable transparent solid masonry panels designed for both interior and exterior use. Built to resist penetration from high-impact ballistics and tested in a variety of applications, VISTABRIK® solid glass blocks have become a permanent fixture in transit, educational, public buildings, correctional facilities, courthouses, embassies and police stations all around the country.

Their durability, low-maintenance and if necessary, low replacement costs, and high level of fire resistance bring important advantages to facilities which are subject to sudden impact, heavy traffic, and vandalism.

Thickset®
Hollow Glass Block
Thickset® Block Vue™ Pattern
Thickset® Block
Vue™ Pattern
Thickset® Block Decora™ Pattern
Thickset® Block
Decora™ Pattern
Thickset® Block Endura™ Pattern
Thickset® Block
Endura™ Pattern

Clear visibility, durable, impact and vandal resistant, bullet resistant, low maintenance, and aesthetically attractive, Vistabrik® and the Thickset® glass block lines are unique products with tremendous versatility as a transparent building material that affords design possibilities limited only to the architect's imagination and vision.

Thickset® Block Vue™ Pattern
The three-times greater face thickness of Thickset® Block versus standard block

Thickset®
  Decora® Decora® Vue® Vue® Endura
Size Nominal/Actual
(mm)
6" x 6" / 6-3/4"
(146mm)
8" x 8" / 7-3/4"
(194mm)
6" x 6" / 6-3/4"
(146mm)
8" x 8" / 7-3/4"
(194mm)
8" x 8" / 7-3/4"
(194mm)
Weight
(lbs/kg)
5.75/2.60 10/4.56 5.75/2.60 10/4.56 10/4.56
Heat Transmission U Value
(Btu/hr ft2 °F)
0.51 0.51 0.51 0.51 0.51
Thermal Resistance2 R Value
(hr ft2 °F/Btu)
1.96 1.96 1.96 1.96 1.96
Thermal Expansion Coef.
(°F)
47 x 10-7 47 x 10-7 47 x 10-7 47 x 10-7 47 x 10-7
Visible Light Transmission3
(%)
50-55 50-55 50-55 50-55 50-55
Shading Coef. 0.65 0.65 0.65 0.65 0.65
Sound Transmission S.T.C. 50 50 50 50 50
Impact Strength
(in-lbs)
60-80 60-80 60-80 60-80 60-80
Compressive Strength
(psi)
2500 2500 2500 2500 2500
Fire Ratings
Time 45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
Masonry Wall Construction
Max Area / Panel (ft2)
100 100 100 100 100
Masonry Wall Construction
Max Ht or Width (ft)
10 10 10 10 10
Non-Masonry Wall Construction
Max Area / Panel (ft2)
94
45 min
60 min
94
45 min
60 min
94
45 min
60 min
94
45 min
60 min
94
45 min
60 min
Non-Masonry Wall Construction
Max Ht or Width (ft)
10.75 10.75 10.75 10.75 10.75
Channel Framing /
Panel Anchor Framing
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min

Vistabrik®
  Vue® Vue® Vue® Stipple
Size Nominal/Actual
(mm)
8" x 8" x 3" /
7-5/8", 3"
(194mm, 76mm)
8" x 3" x 3" /
7-5/8" x 3", 3"
(194 x 76, 76mm)
8" x 8" x 1-1/2" /
7-5/8", 1-1/2"
(194mm, 38mm)
8" x 8" x 3" /
7-5/8", 3"
(194mm, 76mm)
Weight
(lbs/kg)
15/6.80 6/2.72 7.5/3.4 15/6.80
Heat Transmission U Value
(Btu/hr ft2 °F)
0.87 0.87 0.87 0.87
Thermal Resistance2 R Value
(hr ft2 °F/Btu)
1.15 1.15 1.15 1.15
Thermal Expansion Coef.
(°F)
47 x 10-7 47 x 10-7 47 x 10-7 47 x 10-7
Visible Light Transmission3
(%)
80 80 80 80
Shading Coef.        
Sound Transmission S.T.C. 53     53
Impact Strength
(in-lbs)
Exceeds 150 Exceeds 150 Exceeds 150 Exceeds 150
Compressive Strength
(psi)
80,000 80,000 80,000 80,000
Fire Ratings
Time 45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
Masonry Wall Construction
Max Area / Panel (ft2)
100 100 100 100
Masonry Wall Construction
Max Ht or Width (ft)
10 10 10 10
Non-Masonry Wall Construction
Max Area / Panel (ft2)
94
45 min
60 min
94
45 min
60 min
94
45 min
60 min
94
45 min
60 min
Non-Masonry Wall Construction
Max Ht or Width (ft)
10.75 10.75 10.75 10.75
Channel Framing /
Panel Anchor Framing
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min
45 min
60 min
90 min

[ Sitemap ] Vistabrik Facility Armor 
Transport Armor
Vehicle Armor
Body Armor
Body Armor - Facility Armor - Transport Armor
In The News - Milestones - FAQ - Technical Papers - About Us - Contact Us - Careers - Links - Home
Web Site User Agreement and Disclaimer © 1998-2007 Pinnacle Armor. All Rights Reserved.